Exam Name:Sonography Principles and Instrumentation
Certification Provider:ARDMS
Free Question Number:44
Version:v2024-09-05
Rating:
# of views:232
# of Questions views:1850
Go To SPI Questions

LEAVE A REPLY

Your email address will not be published. Required fields are marked *

Exam Question List
Question 1: Which method of sanitizing the transducer would damage piezo...
Question 2: Which pulsed-wave Doppler adjustment would be appropriate to...
Question 3: What occurs when the pulse repetition frequency is less than...
Question 4: What is the primary factor that improves lateral resolution?...
Question 5: Which adjustment resulted in the change from image A to imag...
Question 6: Which index is related to the likelihood of cavitation?...
Question 7: In this image obtained from a tissue-mimicking phantom, whic...
Question 8: Which resolution capability is most affected by spatial puls...
Question 9: What is the primary reason to use compression?...
Question 10: In this image, what does the data below the baseline represe...
Question 11: Which setting can be increased to correct for clutter artifa...
Question 12: Which will affect the gray-scale of a 2-D image?...
Question 13: Which change can be made in order to avoid exceeding the Nyq...
Question 14: Which adjustment would reduce the noise in the Doppler wavef...
Question 15: Which statement characterizes the primary difference between...
Question 16: What is the relationship between overall gain and image brig...
Question 17: What determines the resonant frequency of a pulsed wave tran...
Question 18: What is effected by increasing the color scale?...
Question 19: Which machine setting could cause aliasing to occur?...
Question 20: Which settings will lead to the highest temporal resolution?...
Question 21: What is a potential negative consequence of using a high wal...
Question 22: Which system control adjusts amplification of signals as a f...
Question 23: What does damping in a pulsed-wave transducer affect?...
Question 24: What improves the temporal resolution of color flow imaging?...
Question 25: Which type of display process rescans only the region of int...
Question 26: What happens to the Doppler shift when the angle is changed ...
Question 27: If the pulse repetition frequency is 3 kHz, what is the maxi...
Question 28: What does this image demonstrate? (Exhibit)...
Question 29: What is the benefit of using a wall filter?...
Question 30: How is intensity of an ultrasound beam measured?...
Question 31: During 3-D volume acquisition, the quality of the images is ...
Question 32: Which is a method to reduce noise?...
Question 33: Which color Doppler artifact is visualized in this image? (E...
Question 34: Which change was made after acquiring image A to produce ima...
Question 35: Which factor affects temporal resolution?...
Question 36: Which color control was adjusted in color bar A to produce c...
Question 37: Which factor influences color flow imaging frame rate?...
Question 38: What is the function of M-mode?...
Question 39: Which technique averages individual frames together to impro...
Question 40: During a color Doppler scan, which angle to flow would most ...
Question 41: Which target group is used to evaluate transverse distance m...
Question 42: Which feature is a characteristic of continuous wave Doppler...
Question 43: Which resolution is improved by focusing?...
Question 44: Which factor improves axial resolution?...