Valid H12-425_V2.0-ENU Dumps shared by ExamDiscuss.com for Helping Passing H12-425_V2.0-ENU Exam! ExamDiscuss.com now offer the newest H12-425_V2.0-ENU exam dumps, the ExamDiscuss.com H12-425_V2.0-ENU exam questions have been updated and answers have been corrected get the newest ExamDiscuss.com H12-425_V2.0-ENU dumps with Test Engine here:

Access H12-425_V2.0-ENU Dumps Premium Version
(468 Q&As Dumps, 35%OFF Special Discount Code: freecram)

Online Access Free H12-425_V2.0-ENU Exam Questions

Exam Code:H12-425_V2.0-ENU
Exam Name:HCIP-Data Center Facility Deployment V2.0
Certification Provider:Huawei
Free Question Number:147
Version:v2022-10-26
Rating:
# of views:407
# of Questions views:9063
Go To H12-425_V2.0-ENU Questions

LEAVE A REPLY

Your email address will not be published. Required fields are marked *

Other Version
325 viewsHuawei.H12-425_V2.0-ENU.v2023-08-31.q111
348 viewsHuawei.H12-425_V2.0-ENU.v2023-05-01.q104
Exam Question List
Question 1: What is the maximum IT load supported by the FusionModule200...
Question 2: The EPO status interface of UPS5000-E can choose open or nor...
Question 3: If the FusionModule800 adopts the down pipe, what is the min...
Question 4: The NetEco management system supports user decentralization ...
Question 5: Two UPS5000-E (50kVA power modules) 150kVA, rack 1+1 redunda...
Question 6: What are the possible reason of the excessive noise of the N...
Question 7: If the UPS5000-400K cuts the bypass and closes the maintenan...
Question 8: At present, in the design of the data center, the part ( ) t...
Question 9: UPS5000-A supports the adjustable number of battery cells, w...
Question 10: The relevant standards stipulate that the voltage drop of th...
Question 11: The dry contact signal of UPS5000-E does not support the rem...
Question 12: UPS5000-E can accept the input voltage within the range of (...
Question 13: Huawei's main temperature control solution for small and med...
Question 14: After the PowerEcho is installed, the default user name is a...
Question 15: If a project requires the management system to be connected ...
Question 16: The access control management function of NETECO cannot modi...
Question 17: Traditional UPS. The number of battery cells is not adjustab...
Question 18: Which of the following cladding scenarios does FusionMoudle2...
Question 19: What sensor does FusionModule2000 use to detect whether the ...
Question 20: What security mechanisms does NetEco6000 management system u...
Question 21: What of the following statement of FusionModule2000 v3.0 ver...
Question 22: APM, NR and other UPS products need to be derated at 30 degr...
Question 23: The 2.4G antenna on ECC800 should be installed in ()....
Question 24: Access to the ECC800 by wireless networking is not supported...
Question 25: Users can modify the login password in the () menu of the EC...
Question 26: When the device interface uses the MODBUS-RTU protocol, ( ) ...
Question 27: In this agenda, the refrigerant has undergone the change pro...
Question 28: Which of the following features are standard features of NET...
Question 29: Batteries of different capacities, different specifications,...
Question 30: In FusionModule1000B series solutions, when 2N power supply ...
Question 31: The operating temperature range of FusionModule800 is -40-45...
Question 32: The FusionModule800 does not need to be charged with refrige...
Question 33: Which of the following alarm functions does the main circuit...
Question 34: FusionModule2000UPS is listed as an integrated UPS and suppo...
Question 35: When a fire breaks out in the box and the fire extinguishing...
Question 36: The UPS5000-E (25-75kVA) bypass module has a maximum output ...
Question 37: UPS5000-A has built-in SNMP and ModBus card, which reduces t...
Question 38: If the customer's load cannot be powered off, what should be...
Question 39: Which is not part of the routine maintenance item of the ECC...
Question 40: What methods does the FusionModule800 power input support?...
Question 41: Which of the following fan control modes are supported by Ne...
Question 42: NETCOL5000-C needs to manually adjust the water valve to the...
Question 43: UPS5000-E only needs to select ( ) to easily realize the N+X...
Question 44: After installing the top-out fan on the UPS5000, you need to...
Question 45: The ECC800 is the core component of local management of the ...
Question 46: Which of the following is a component of Huawei's indirect e...
Question 47: UPS5000-series modular UPS product features are similar to w...
Question 48: Which type of circuit breaker used in the sub-circuit of the...
Question 49: What is the range of the number of battery cabinets in the F...
Question 50: What core differentiated features of FusionModule800 can shi...
Question 51: What is the lightning protection level of the integrated UPS...
Question 52: Fusionlodule500 uses natural heat dissipation....
Question 53: ( ) indicates the amount of electricity that a fully charged...
Question 54: During the use of the battery pack, the appearance is normal...
Question 55: The form of humidifier adopted by the row-level chilled wate...
Question 56: The smart ETH socket supports up to () cascades....
Question 57: During the use of the battery, in order to reduce the deteri...
Question 58: FusionModule800 version 3.0 supports face recognition functi...
Question 59: PDU8000 precision power distribution cabinet supports the mo...
Question 60: Which of the following voltage systems does the UPS5000-E su...
Question 61: The main unit of UPS5000-(DKVA power module) occupies a smal...
Question 62: Three groups of 9AH battery packs are connected in parallel ...
Question 63: Which of the following components can control the lighting i...
Question 64: The NETCol5000-A36W air conditioner has a light load initial...
Question 65: In the UPS5000 configuration, the power supply reliability l...
Question 66: When the ECC800 detects that the connection signal to the de...
Question 67: Which of the following descriptions for the configuration of...
Question 68: Which of the FusionModule800 needs on-site construction surv...
Question 69: The bypass module of UPS5000-E-200K (50kVW power module) is ...
Question 70: The access control management function of the Netco6000 mana...
Question 71: Common monitoring software structures include B/S and C/S st...
Question 72: Which of the following are indoor products of Huawei data ce...
Question 73: Huawei NECOL5000-A row-level precision air conditioner elimi...
Question 74: Regarding the overload capacity of UPS5000-E, which of the f...
Question 75: What is the size of the screen of the air conditioner of Fus...
Question 76: The location of the data center needs to be evaluated () fac...
Question 77: When the internal short circuit of the battery occurs, the c...
Question 78: To modify the plan view of the ECC800 micro-module, you need...
Question 79: Compared with NXR, which of the following indicators of UPS5...
Question 80: What methods does Fusi onllodul e800 air conditioner configu...
Question 81: When the inspection, maintenance and repair of electrical in...
Question 82: When the Huawei air-cooled air-conditioning compressor is tu...
Question 83: Fusionllodule2000 UPS is listed and configured?...
Question 84: ECC800 does not support historical data export....
Question 85: What is the possible cause of the high discharge temperature...
Question 86: The temperature control laboratory has passed the GMPI certi...
Question 87: The maximum charging capacity of UPS5000-E is ()...
Question 88: UPS5000-E can maintain high efficiency in a wide load range ...
Question 89: Which of the following technology or solution can reduce PUE...
Question 90: The similar models of Eaton and UPS5000-A 30kVA120kVA are ()...
Question 91: Which of the following modules are included in the UPS5000-E...
Question 92: RH2288 server supports () power input....
Question 93: When a user uses the NETECC APP on the PAD to query the PUE ...
Question 94: What components can the NetCol 8000-C room-level chilled wat...
Question 95: Which of the following functions does PDU8000 precision powe...
Question 96: NETECO's report functions are displayed in various forms, wi...
Question 97: All fire-fighting cables running in the FusionModule1000 are...
Question 98: What is the maximum capacity of the power module of the UPS5...
Question 99: One sunroof actuator can drive up to () sunroof solenoid val...
Question 100: Which of the following certifications has the PDU8000 precis...
Question 101: What is the cabinet depth of Huawei Micro Module 2000? (Mult...
Question 102: The optional temperature and humidity sensor of UPS5000 does...
Question 103: UPS5000-E (50kVA power module) single rack can accommodate u...
Question 104: () can convert POE signal into WIFI signal....
Question 105: When the NetCol8000-C room-level chilled water intelligent t...
Question 106: Which type of compressor is used in new room-level air cooli...
Question 107: The function of the check valve in the NetCol5000-A air cond...
Question 108: UPS5000-E 100kVA, the input switch to be selected by the mac...
Question 109: Huawei's main temperature control solution for small and med...
Question 110: When the power density of a single cabinet is greater than 1...
Question 111: Which of the following functions belong to the FusionModule2...
Question 112: The FusionModule2000 battery is listed in the scene, support...
Question 113: ATS (Automatic Transfer Switch) must overflow the manual ope...
Question 114: The technical essential of the vacuum pumping action of the ...
Question 115: When NETCOL5000-C is debugging the drainage equipment, lift ...
Question 116: What are the factors that affect the service life of the bat...
Question 117: The UPS5000-E battery adopts the design of no center line, w...
Question 118: FusionModule2000 IT cabinet seismic rating?...
Question 119: In ECO mode, when the input is stable, the UPS works in () s...
Question 120: In order to realize the remote notification of the alarm tim...
Question 121: Huawei Neteco network management supports mobile APP managem...
Question 122: UPS5000-E (25-125kVA) does not support the Battery function....
Question 123: What is the channel width of Huawei FusionModule2000?...
Question 124: The domestic power supply system is 380v/50Hz....
Question 125: A single row of FusionModule 2000 supports a maximum of 48 c...
Question 126: Huawei air-cooled air conditioners (25kw and 42kw) one indoo...
Question 127: What operations can be performed in the NetEco "Report Task"...
Question 128: What are the i3 features of FusionModule2000 V3.0 include? (...
Question 129: One NetCol520 chilled water distribution units can maximum s...
Question 130: NETECOL can assign operation rights to user groups, or direc...
Question 131: When calculating the battery capacity, the battery discharge...
Question 132: What are the alarm management functions supported by the ECC...
Question 133: BCB-BOX is an optional part of UPS5000-E, used for connectio...
Question 134: A single row of FusionModule2000 supports a maximum of ( ) c...
Question 135: What are the certifications of FusionModule500&FusionMod...
Question 136: The skylight actuator can control the reversing skylight of ...
Question 137: Which of the following are the working modes of the runner n...
Question 138: Regarding the circuit breaker statement, which of the follow...
Question 139: When the distance between the outdoor unit and the sea is 0....
Question 140: In the single cabinet configuration scenario, which of the f...
Question 141: A system is configured with 15min battery backup time, and t...
Question 142: NETCOL5000-A35KW uses an electronic expansion valve....
Question 143: In the parallel steps of the UPS5000-E, the reason for using...
Question 144: When creating a camera in NETECO, in addition to obtaining t...
Question 145: FusionModule800 3.0 closed channel hot and cold channels are...
Question 146: FusionModule500&FusionModule800 remote WEB interface mon...
Question 147: In a project that requires the deployment of three-layer tem...