Valid H12-425_V2.0 Dumps shared by ExamDiscuss.com for Helping Passing H12-425_V2.0 Exam! ExamDiscuss.com now offer the newest H12-425_V2.0 exam dumps, the ExamDiscuss.com H12-425_V2.0 exam questions have been updated and answers have been corrected get the newest ExamDiscuss.com H12-425_V2.0 dumps with Test Engine here:

Access H12-425_V2.0 Dumps Premium Version
(468 Q&As Dumps, 35%OFF Special Discount Code: freecram)

Online Access Free H12-425_V2.0 Exam Questions

Exam Code:H12-425_V2.0
Exam Name:HCIP-Data Center Facility Deployment V2.0
Certification Provider:Huawei
Free Question Number:110
Version:v2023-08-07
Rating:
# of views:512
# of Questions views:11561
Go To H12-425_V2.0 Questions

Recent Comments (The most recent comments are at the top.)

Blake - Jul 02, 2025

I didn't believe the exam questions online for i thought they are not accurate, but i have only a few days to prapare for the exam, so i have to buy them, then i passed with a high score. Please trust these valid and accurate H12-425_V2.0 exam questions!

LEAVE A REPLY

Your email address will not be published. Required fields are marked *

Other Version
227 viewsHuawei.H12-425_V2.0.v2024-10-30.q190
Exam Question List
Question 1: When the polling function is turned on, the running machine ...
Question 2: If the FusionModule800 adopts the down pipe, what is the min...
Question 3: The maximum charging capacity of UPS5000-E is ()...
Question 4: What are the certifications of FusionModule500&FusionMod...
Question 5: In NETECO's report management, which of the following types ...
Question 6: The NetEco management system supports user decentralization ...
Question 7: When Huawei air-cooled air conditioner is installed, the req...
Question 8: How many 12v batteries can the optional battery inspection i...
Question 9: The type of UPS5000-E is ( )
Question 10: After the UPS5000-E is installed, what are the key points fo...
Question 11: The external maintenance bypass of the UPS system generally ...
Question 12: Regarding the adjustable battery of UPS5000-E, when one batt...
Question 13: The host should be set to () when the UPS5000 series multi-r...
Question 14: Through the optional battery inspection instrument, the ( ) ...
Question 15: What is the maximum power of the IT cabinet of FusionModule5...
Question 16: BCB-BOX is an optional part of UPS5000-E, used for connectio...
Question 17: Which manufacturers have 50KVA power modules? (Multiple choi...
Question 18: When the maintenance engineer arrives at the customer site, ...
Question 19: The operating temperature range of FusionModule800 is -40-45...
Question 20: What are the possible reason of the excessive noise of the N...
Question 21: When the outdoor unit of Huawei air-cooled air conditioner i...
Question 22: What is the maximum capacity of the power module of the UPS5...
Question 23: The intelligent busway can replace the precision configurati...
Question 24: Domains can be created in NETECO, such as campuses, building...
Question 25: The ECC800 does not support the function of sending alarm in...
Question 26: Which of the following components can control the lighting i...
Question 27: UPS5000-E only needs to select ( ) to easily realize the N+X...
Question 28: Video can only be viewed on NETECO after the video camera ha...
Question 29: When a user uses the NETECC APP on the PAD to query the PUE ...
Question 30: The access control management function of the Netco6000 mana...
Question 31: The NETCol5000-A36W air conditioner has a light load initial...
Question 32: What are the main reasons for the energy saving effect of cl...
Question 33: Which of the following resources can be managed by the capac...
Question 34: The NETECO system can define the alarm sound for the alarms ...
Question 35: One NetCol520 chilled water distribution units can maximum s...
Question 36: When the single unit is working, the load of the UPS2000-G i...
Question 37: The PDU8000 precision power distribution cabinet supports th...
Question 38: Which of the following descriptions of the iPower function o...
Question 39: On-demand deployment and avoiding over-investment are the on...
Question 40: Which of the following models has the widest input voltage r...
Question 41: The AI/DI port on the access control actuator supports to co...
Question 42: In the naming of UPS5000-E-120K-HASBS, the meaning of the le...
Question 43: Which of the following functions or components does the UPS6...
Question 44: FusionModule2000 IT cabinet seismic rating?...
Question 45: What is the reasonable exhaust pressure range for NETCOL5000...
Question 46: Which of the following statements about UPS5000-E are correc...
Question 47: Which of the following UPS models supports bypass hot swap? ...
Question 48: The function of the back-feed protection card is that when t...
Question 49: The recommended installation location of the smart ETH socke...
Question 50: APM, NR and other UPS products need to be derated at 30 degr...
Question 51: The () components of Huawei NETCOL5000-A in-line precision a...
Question 52: Suppose a certain battery specification stipulates that the ...
Question 53: Compared with the upper air duct air supply, the upper air d...
Question 54: Considering that the UPS system is fully configured in the e...
Question 55: Regarding the overload capacity of UPS5000-E, which of the f...
Question 56: Fusion Module2000 is an outdoor prefabricated integrated dat...
Question 57: During the use of the battery, in order to reduce the deteri...
Question 58: What methods are supported by the FusionModule800 UPS config...
Question 59: In the () setting interface, you can set the linkage rules o...
Question 60: After the PowerEcho is installed, the default user name is a...
Question 61: When the battery status of the UPS2000G is NA, it may be ()....
Question 62: The FusionModule800 does not need to be charged with refrige...
Question 63: NetCol5000-c row-level chilled water intelligent temperature...
Question 64: The default battery charging voltage of UPS2000-G is () V/CE...
Question 65: The device is connected to the ECC800 monitoring system thro...
Question 66: When UPS5000-E is installed in parallel, it is not necessary...
Question 67: When the device interface uses the MODBUS-RTU protocol, ( ) ...
Question 68: UPS5000-E is a high-efficiency UPS. Which of the following s...
Question 69: The damage of NETCOL5000-C thermal insulation cotton may cau...
Question 70: The terminal power of the battery in the open circuit state ...
Question 71: In ECO mode, when the input is stable, the UPS works in () s...
Question 72: At present, in the design of the data center, the part ( ) t...
Question 73: The ECC800 is the core component of local management of the ...
Question 74: Huawei's main temperature control solution for small and med...
Question 75: On the NETECO interface, a module can only bind () ECC800 de...
Question 76: A single row of FusionModule 2000 supports a maximum of 48 c...
Question 77: Which of the following voltage systems does the UPS5000-E su...
Question 78: UPS5000-A supports the adjustable number of battery cells, w...
Question 79: The NetEco6000 management system can provide monitoring of t...
Question 80: When the UPS is in parallel, the input phase sequence of the...
Question 81: When the Huawei air-cooled air-conditioning compressor is tu...
Question 82: Which of the following alarm functions does the PDU8000 prec...
Question 83: All fire-fighting cables running in the FusionModule1000 are...
Question 84: UPS5000-A can significantly reduce the harmonic pollution to...
Question 85: What security mechanisms does NetEco6000 management system u...
Question 86: The closed hot and cold aisle system can improve cooling eff...
Question 87: What sensor does FusionModule2000 use to detect whether the ...
Question 88: Regarding the integrated UPS5000-E120K-HASBS statements, whi...
Question 89: When UPS2000-G shuts down the single machine of the shutdown...
Question 90: FusionModule2000 product configuration framework, which of t...
Question 91: FusionModule500&FusionModule800 display brand optional (...
Question 92: Regarding intelligent battery management in UPS5000-A, which...
Question 93: NetCol8000-A013U 13kW small cooling capacity temperature con...
Question 94: The anti-seismic components of UPS5000 are suitable for eart...
Question 95: What is the system efficiency of UPS5000-E?...
Question 96: A system is configured with 5H battery backup time, and the ...
Question 97: Compared with high-frequency machines, industrial frequency ...
Question 98: UPS5000-E 100kVA, the input switch to be selected by the mac...
Question 99: The domestic power supply system is 380v/50Hz....
Question 100: During the use of the battery, in order to balance the capac...
Question 101: NETECO cannot perform centralized and unified management of ...
Question 102: Which of the following cladding scenarios does FusionMoudle2...
Question 103: Which of the following are indoor products of Huawei data ce...
Question 104: What is the range of the number of battery cabinets in the F...
Question 105: NETCOL9000-A100KW is a dual system, and the standard configu...
Question 106: What are the main components of the natural cooling source s...
Question 107: The power systems of FusionModule800 and FusionModule500 are...
Question 108: ( ) marks the fully charged battery, and discharge it to the...
Question 109: Which of the following modules are included in the UPS5000-E...
Question 110: Which of the following features are standard features of NET...