Exam Code:CDCS
Exam Name:EXIN EPI Certified Data Centre Specialist
Certification Provider:EXIN
Free Question Number:56
Version:v2026-04-10
Rating:
# of views:156
# of Questions views:1682
Go To CDCS Questions

LEAVE A REPLY

Your email address will not be published. Required fields are marked *

Other Version
317 viewsEXIN.CDCS.v2024-12-21.q25
Exam Question List
Question 1: In order to save energy, you are going to install an automat...
Question 2: The logical overview of the data center looks as pictured. T...
Question 3: A customer requires THDi from the UPS not to exceed 3% and w...
Question 4: When are the wet bulb and dry bulb temperatures identical?...
Question 5: EMF shielding material needs to be installed as EMF levels f...
Question 6: ICT rack consumes 3 kW with #T ~11 °C (20 °F). Calculate req...
Question 7: What is a significant difference between a halocarbon gas-ba...
Question 8: Where should raised-floor installation start?...
Question 9: Two servers stacked with no gap (metal-to-metal). What heat ...
Question 10: A computer room with raised floor and hot/cold aisles is des...
Question 11: The 'maximum exposed area' of the fire-rated glass is define...
Question 12: What is a potential disadvantage of using a hypoxic-based fi...
Question 13: When installing a raised floor, can we use a spirit level ba...
Question 14: You are changing the design of the fire suppression system f...
Question 15: Do you need to consider bullet (ballistic) protection when d...
Question 16: An air-conditioner unit needs to be selected. Two types are ...
Question 17: Do all residual current devices (RCDs) use the same operatin...
Question 18: What indicates the breaking capacity of a fuse or breaker?...
Question 19: What mainly affects the cooling capacity of a raised floor t...
Question 20: A computer room needs to be fitted out with a gas-based fire...
Question 21: The building in which the computer room is housed is require...
Question 22: The UPS of a data center, with an ANSI/TIA-942 Rating-4, is ...
Question 23: A data center has its own power supply from the public utili...
Question 24: What indicates the overcurrent of a fuse or breaker?...
Question 25: You need to install a highly sensitive fire detection system...
Question 26: Should aerosol cleaning solutions be used in the computer ro...
Question 27: What is the redundancy setup shown in the diagram?...
Question 28: Smoke sensors must be installed in the computer room. What i...
Question 29: Do you need to consider bullet (ballistics) protection when ...
Question 30: The data center has been in operation for about 1 year and 2...
Question 31: What is the focus of the Open Compute Project (OCP)?...
Question 32: Racks with 1.0 m depth and cold aisle containment with 3 per...
Question 33: Which formula is correct?
Question 34: You have three UPS systems connected in parallel. The UPS sy...
Question 35: What is the preferred way to measure dust levels in the comp...
Question 36: How is the PUE ratio calculated?...
Question 37: A data center scores Rated-3 in mechanical, Rated-4 in elect...
Question 38: What is the floor loading requirement for a Rated-3 data cen...
Question 39: The temperature in the computer room is being increased from...
Question 40: Maximum exposed area of fire-rated glass is 2 m², but the wi...
Question 41: What is the advantage or disadvantage of using MPO (Multi-fi...
Question 42: What is the calculation for the desired attenuation factor f...
Question 43: What is the minimum requirement for the power feeds to the b...
Question 44: Does hot/cold aisle containment impact PUE?...
Question 45: When designing a data center network, your company wants to ...
Question 46: You are working with a customer who requires a guarantee tha...
Question 47: Given: A = attenuation in dB, R = real measured value, M = m...
Question 48: You need to determine the strategy for the cooling audit. Al...
Question 49: What is the main disadvantage of using a ToR (Top of Rack) d...
Question 50: You are allowed to use a calculator for this question. A com...
Question 51: A battery bank has 800 Ah total capacity. How much charging ...
Question 52: What is the main advantage of using an End-of-Row (EoR) desi...
Question 53: In which stage of the data center life cycle does commission...
Question 54: What is the main reason to install Earth Leakage protection?...
Question 55: The UPS of a data center with ANSI/TIA-942 Rating-4 is insta...
Question 56: A data center requires an audit to find out whether it confo...